Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
tools:actsim [2023/04/14 15:22] rajit [Configuration file] |
tools:actsim [2023/04/16 11:32] (current) rajit [Using files for test data] |
||
---|---|---|---|
Line 303: | Line 303: | ||
} | } | ||
</ | </ | ||
+ | |||
+ | This example will also need a file '' | ||
===== Mixed-signal simulations ===== | ===== Mixed-signal simulations ===== | ||
Line 314: | Line 316: | ||
===== Configuration file ===== | ===== Configuration file ===== | ||
+ | |||
+ | An ACT configuration file can be read into '' | ||
+ | |||
==== CHP configuration options ==== | ==== CHP configuration options ==== | ||
- | The standard simulation library (in the sim namespace) uses a few configuration file settings to pick the names | + | < |
- | of the files for I/O. | + | begin sim |
+ | begin chp | ||
+ | int inf_loop_opt 0 | ||
+ | end | ||
+ | end | ||
+ | </code> | ||
+ | '' | ||
< | < | ||
- | string | + | begin sim |
+ | begin chp | ||
+ | int default_delay 0 | ||
+ | real default_leakage 0 | ||
+ | int default_area 0 | ||
+ | end | ||
+ | end | ||
</ | </ | ||
- | Change this parameter to modify | + | These set default simulation parameters for CHP processes. The default delay sets the value for each non-skip basic statement (send, receive, assignment) in a CHP program. The default |
- | Alternatively, | ||
< | < | ||
- | string_table | + | begin sim |
+ | begin chp | ||
+ | int debug_metrics 0 | ||
+ | end | ||
+ | end | ||
</ | </ | ||
- | If this parameter | + | If this is set to 1, then debugging messages are printed out showing |
- | Other simulation | + | ==== Mixed-signal |
+ | The mixed-signal simulation parameters are used to configure the interface to Xyce, and are contained in a sim.device block. | ||
< | < | ||
- | int sim.chp.inf_loop_opt 0 | + | begin sim |
+ | begin device | ||
+ | # put mixed-signal parameters here | ||
+ | end | ||
+ | end | ||
</ | </ | ||
- | '' | + | The parameters are |
+ | < | ||
+ | real timescale 1e-12 | ||
+ | </ | ||
+ | This is used for the time resolution of the Xyce output trace files, | ||
< | < | ||
- | int sim.chp.default_delay 10 | + | real analog_window 0.05 |
</ | </ | ||
- | This is the default delay for each non-skip basic statement (send, receive, assignment) in a CHP program. | + | This specifies when an analog signal output should be treated as a digital 0 or digital 1. The value 0.05 means within 5% of the rail-to-rail voltage. So for a 1V power supply, this would be 0.95 for a digital 1 threshold, and 0.05 for a digital 0 threshold. |
< | < | ||
- | int sim.chp.default_leakage 0 | + | int case_for_sim 1 |
</ | </ | ||
- | This is the default leakage associated with a process | + | SPICE is case-insensitive, |
< | < | ||
- | int sim.chp.default_area 0 | + | real settling_time 1e-12 |
</ | </ | ||
- | This is the default area associated with a CHP process (square microns). | + | This is the settling time parameter for the built-in ADC device used to convert between the digital and analog signals. |
< | < | ||
- | int sim.chp.debug_metrics 0 | + | int dump_all 1 |
</ | </ | ||
- | If this is set to 1, then debugging messages | + | If this is true, all voltage signals should be saved to the output trace file. Otherwise, only the interface signals |
+ | |||
+ | < | ||
+ | string output_format " | ||
+ | </ | ||
+ | This specifies which output trace file formats should be generated from the underlying analog simulation engine. Any number of colon-separated formats are supported, but only one of the built-in formats (raw, prn, etc) can be used. | ||
+ | |||
+ | < | ||
+ | int waveform_steps 10 | ||
+ | real waveform_time 10e-12 | ||
+ | </ | ||
+ | The digital input is converted to a ramp before being fed to the analog simulation. This specifies the duration and number of steps used for the conversion. | ||
+ | |||
+ | < | ||
+ | string model_files " | ||
+ | </ | ||
+ | By default, the simulation will look for the file '' | ||
+ | |||
+ | < | ||
+ | string outfile " | ||
+ | </ | ||
+ | This is the name of the trace file output that is generated. | ||
+ | |||
+ | < | ||
+ | real stop_time 100e-12 | ||
+ | </ | ||
+ | This is the time at which the trace file output should stop. | ||
+ | |||
+ | ==== Standard sim namespace helper functions ==== | ||
+ | |||
+ | The standard simulation library (in the sim namespace) uses a few configuration file settings to pick the names | ||
+ | of the files for I/O. | ||
+ | |||
+ | < | ||
+ | begin sim | ||
+ | begin file | ||
+ | string prefix " | ||
+ | end | ||
+ | end | ||
+ | </ | ||
+ | Change this parameter to modify the default file names used by the file I/O library used by the standard simulation namespace. | ||
+ | |||
+ | Alternatively, a file name table can be specified whose entries are the names of the files to be used for each file ID (0 = first entry, 1 = second entry, etc.) | ||
+ | < | ||
+ | begin sim | ||
+ | begin file | ||
+ | string_table name_table " | ||
+ | end | ||
+ | end | ||
+ | </ | ||
+ | If this parameter is specified, then the prefix parameter is ignored. | ||
+ |